image_pdfimage_print

Underground Shelters Gallery

S16x8 Underground Shelter End Wall Construction

S16x10 Bomb Shelter Pictures

S16x16 Bomb Shelter Pictures

S16x24 Bomb Shelter Pictures

S16x40 Bomb Shelter Pictures

S16x80 Bomb Shelter Pictures

 

Bomb Shelter Prices

International and Domestic Price Disclaimer

PRICES are for shelters sold and delivered in the United States. Pricing for shelters exported will be quoted on an individual basis to cover the EXPORT LICENSE from the United States Department of Defense, import taxes, tariffs, incoming inspection, insurance, local agent fees and other charges specific to the country of delivery.

PRICES OF AND FEATURES INCLUDED ON S10 AND S16 BOMB SHELTERS
BOMB SHELTER MODEL
MODEL C11-CIV
110 SF Useable
GUARD S10x14-CIV NOMAD S10X20-CIV S16X16-CIV OUTPOST S10X40-MIL S16X24-MIL S16X40-MIL
PRICE $116,400 $172,500 $226,400 $237,540 $326,400 $340,570 $453,370
6.5KW INTERNAL EMP-SHIELDED GENERATOR 0 0 0 0 1 1 1
GENERATOR SEAM NBC AIR 0 0 0 0 1 1 1
SOLAR POWER PACKAGE 1 KW 2 KW 2 KW 2 KW 0 0 0
SOLAR PANEL EMP VAULT 1 1 1 1 0 0 0
LED WHITE LIGHTS 2 2 2 2 4 3 5
LINEAR FT. SHELVING 110 110 240 128 480 192 320
ELECTRIC STOVE 0 0 0 0 1 1 1
METHANOL STOVE 1 1 1 1 0 0 0
ELECTRIC WATER HEATER 0 0 0 0 1 1 1
METHANOL WATER HEATER 0 1 1 1 0 0 0
TWIN BUNK BED 1 bunk
or 1 sofa
0 0 0 0 0 0
FULL BUNK BED 0 1 2 2 2 2 2
KITCHEN TABLE 0 1 1 1 1 1 1
KITCHEN CHAIR 0 4 4 4 4 4 4
SOFA 1 bunk
or 1 sofa
0 0 0 0 0 1

 

FEATURES INCLUDED ON S10 AND S16 BOMB SHELTERS
NBCE PROTECTION
NBC DECONTAMINATION SOLUTION 1
BLAST VALVES, PAIR 1
SEISMIC JOINT 2
UV STERILIZATION 1
TEDA CARBON NBC BIBO AIR FILTRATION 1
RADIATION METER 1
CHEMICAL TEST KIT 1
EMP PERSONAL ELECTRONICS VAULT 1
WARRANTY
30 YEAR CATHODIC CORROSION PROTECTION/STRUCTURAL WARRANTY 1
40 YEAR WARRANTY UPGRADE
50 YEAR WARRANTY UPGRADE
ELECTRICAL
BATTERY BANK 1
INVERTER AC CIRCUIT BREAKER PANEL 1
SOLAR TRICKLE CHARGER FOR BATTERY BANK 1
DC CIRCUIT BREAKER PANEL 1
ENG. STDS. ABYC, ANSI, API, ASHRAE, ASME, MIL, POP 1
AIR
LOW-TEMPERATURE DE-HUMIDIFER 1
BREATHING SEAM AIR SUPPLY 1
AIR INLET/OUTLET MANIFOLD PATENT PENDING 2
DUST AIR FILTRATION 1
AIR BLOWER 2
ENTRANCE/HATCH
45 DEG WALK-IN EWAY/30X60 IN. HATCH 1
68 DEG EMERGENCY EWAY/30X60 IN. HATCH UPGRADE
EMERGENCY JACK 1
COOKING
MICROWAVE OVEN 1
STORAGE/WORKSPACE/PRIVACY
KITCHEN COUNTER 1
KITCHEN CABINET 1
BATHROOM CABINET
WALLS 1
DOOR 1
INTERIOR DOOR LOCK 1
PLUMBING
KITCHEN SINK 1
BATHROOM SINK 1
CONVENTIONAL SHOWER 1
WATER FILTRATION 1
SUMP PUMP 1
CONVENTIONAL FLUSH TOILET 1
TOILET ROOM VENTING 24/7 1
120 VAC SEWAGE LIFT STATION 1
1,000 GALLON SEPTIC TANK 1
SEPTIC LEACH FIELD 1
COMMUNICATIONS
SCANNER, CABLES, ANTENNA 1
HAM RADIO, CABLES, ANTENNA 1
ANTENNA MAST UPGRADE
EMP RADIO/SCANNER ENCLOSURE 1
CONVENTIONAL PROTECTION
SMOKE DETECTOR 1
FIRE DETECTOR 1
CARBON MONOXIDE DETECTOR 1
FIRE EXTINGUISHER 1

Military and Civilian Bomb Shelters

Military and Civilian S-Series underground bomb shelters listed here are meet MIL STD 188-125 EMP shielding requirements. The CIV shelters are solar powered. The MIL shelters are generator-powered using an internal EMP-shielded generator meeting MIL STD 188-125.

The S-Series Bomb Shelters NORAD Sells Includes Safety Equipment, Power, Life Support, Plumbing and Furniture

All S-Series Underground Blast Shelters Provide Include:
Chemical Protection Biological Protection Radiation Protection Corrosion Protection
Nuclear Blast Protection Conventional Blast Protection EMP Protection Intruder Protection
Flood Protection Fire Protection Wind Protection Target Acquisition Protection
PLUMBING
Hot Water Heater Hot and Cold Running Water Bathroom Sink Kitchen Sink
Fiberglass Shower Flush Toilet Sewage/Septic System Privacy Walls
Locking Bathroom Door Bathroom Negative Air Pressure Plumbing Equipment and Installation
ELECTRICAL POWER
6.5 KW Internal diesel EMP-Shielded Generator Diesel Fuel Tank 800 Gal. Diesel Fuel Diesel Fuel Additives
Battery Bank Battery Bank Solar Maintenance Pressurized Generator Room Generator Noise Reduction
EMP Shielded Storage Vault Circuit Breakers Electrical Equipment and Installation
LIFE SUPPORT
Air Sterilization and Filtration Drinking Water Sterilization and Filtration Spare Air Filters Low-Temperature Dehumidifier
LED Lights
COOKING
Kitchen Stove Microwave Oven
SAFETY EQUIPMENT
Radiation Meter Chemical Agent Test Kit HAM Radio Police Scanner
Antenna Equipment and Installation Hatch Emergency Jack
FURNITURE
Lights Bunk Beds Mattresses Kitchen Table
Kitchen Chairs Kitchen Cabinets Bathroom Closet In-Wall Storage
Sofa Eight to 10 Foot Ceilings Entranceway and Hatch

Formal Cathodic Protection System

All S-Series underground bomb shelters include a formal cathodic protection system using dielectric epoxy and sacrificial anodes protecting the shelter from corrosion, and a 30 year structural warranty.

Sample Prices

S-Series underground bomb shelter prices listed here are examples, are subject to change, and are based on specific configurations; your needs might vary.

S-Series Underground Blast Shelters Provide Protection from:

S-Series Underground Blast Shelters Provide Protection from:
RADIATION
Nuclear Fallout Nuclear Plant Accident Dirty Bomb Full-scale Protracted Nuclear War
BIOLOGICAL AND CHEMICAL THREATS
Biological Weapon Biological Facility Accident Bacterial and Viral Outbreak Chemical Weapon
Severe Pollution Chemical Laboratory Accident Water Supply Contamination
WAR& TERRORISM
Nuclear Bomb Blast Conventional Bomb Blast Coordinated Terror Foreign Invasion
POWER AND INFRASTRUCTURE FAILURE
Electromagnetic Pulse High Altitude Electromagnetic Pulse Coronal Ejection Cyber Attack
SOCIETAL BREAKDOWN
Economic Collapse Computer Infrastructure Failure Power Grid Failure Riot
Local Violence Civil Unrest Home Invasion Random Violence
NATURAL DISASTER
Forest Fire Earthquake Drought Flood
Tornado Hurricane Typhoon Monsoon
Tsunami Cyclone Famine Epidemic
Share